Hypothetical combination,Input or result,Your project inputs / Calculated result,Value,Unit,Operation A,Your project inputs,Filling valves,24,Quantity, A,Your project inputs,Filling time,4.8,s, A,Your project inputs,Filling fraction of revolution,0.6,0…1, A,Step-by-step substitution from the stated inputs,Bottle rate (Bottles/h) / 1,86400.0,,( [Filling valves: 24 Quantity] × 3600) A,Step-by-step substitution from the stated inputs,Bottle rate (Bottles/h) / 2,51840.0,,(( [Filling valves: 24 Quantity] × 3600) × [Filling fraction of revolution: 0.6 0…1] ) A,Step-by-step substitution from the stated inputs,Bottle rate (Bottles/h) / 3,10800.0,Bottles/h,((( [Filling valves: 24 Quantity] × 3600) × [Filling fraction of revolution: 0.6 0…1] ) ÷ [Filling time: 4.8 s] ) A,Calculated result,Bottle rate,10800.0,Bottles/h, B,Your project inputs,Filling valves,24,Quantity, B,Your project inputs,Filling time,7.2,s, B,Your project inputs,Filling fraction of revolution,0.6,0…1, B,Step-by-step substitution from the stated inputs,Bottle rate (Bottles/h) / 1,86400.0,,( [Filling valves: 24 Quantity] × 3600) B,Step-by-step substitution from the stated inputs,Bottle rate (Bottles/h) / 2,51840.0,,(( [Filling valves: 24 Quantity] × 3600) × [Filling fraction of revolution: 0.6 0…1] ) B,Step-by-step substitution from the stated inputs,Bottle rate (Bottles/h) / 3,7200.0,Bottles/h,((( [Filling valves: 24 Quantity] × 3600) × [Filling fraction of revolution: 0.6 0…1] ) ÷ [Filling time: 7.2 s] ) B,Calculated result,Bottle rate,7200.0,Bottles/h, C,Your project inputs,Filling valves,36,Quantity, C,Your project inputs,Filling time,4.8,s, C,Your project inputs,Filling fraction of revolution,0.6,0…1, C,Step-by-step substitution from the stated inputs,Bottle rate (Bottles/h) / 1,129600.0,,( [Filling valves: 36 Quantity] × 3600) C,Step-by-step substitution from the stated inputs,Bottle rate (Bottles/h) / 2,77760.0,,(( [Filling valves: 36 Quantity] × 3600) × [Filling fraction of revolution: 0.6 0…1] ) C,Step-by-step substitution from the stated inputs,Bottle rate (Bottles/h) / 3,16200.0,Bottles/h,((( [Filling valves: 36 Quantity] × 3600) × [Filling fraction of revolution: 0.6 0…1] ) ÷ [Filling time: 4.8 s] ) C,Calculated result,Bottle rate,16200.0,Bottles/h, D,Your project inputs,Filling valves,36,Quantity, D,Your project inputs,Filling time,7.2,s, D,Your project inputs,Filling fraction of revolution,0.6,0…1, D,Step-by-step substitution from the stated inputs,Bottle rate (Bottles/h) / 1,129600.0,,( [Filling valves: 36 Quantity] × 3600) D,Step-by-step substitution from the stated inputs,Bottle rate (Bottles/h) / 2,77760.0,,(( [Filling valves: 36 Quantity] × 3600) × [Filling fraction of revolution: 0.6 0…1] ) D,Step-by-step substitution from the stated inputs,Bottle rate (Bottles/h) / 3,10800.0,Bottles/h,((( [Filling valves: 36 Quantity] × 3600) × [Filling fraction of revolution: 0.6 0…1] ) ÷ [Filling time: 7.2 s] ) D,Calculated result,Bottle rate,10800.0,Bottles/h, A→D,Separate and combined changes from A,Bottle rate / First input alone: C − A,5400.0,Bottles/h, A→D,Separate and combined changes from A,Bottle rate / Second input alone: B − A,-3600.0,Bottles/h, A→D,Separate and combined changes from A,Bottle rate / Both inputs: D − A,0.0,Bottles/h, A→D,Separate and combined changes from A,Bottle rate / Sum of the two separate changes,1800.0,Bottles/h, A→D,Separate and combined changes from A,Bottle rate / Combined change minus that sum,-1800.0,Bottles/h,