Hypothetical combination,Input or result,Your project inputs / Calculated result,Value,Unit,Operation A,Your project inputs,Before: Measured energy,96,kWh, A,Your project inputs,Before: Good bottles,24000,Quantity, A,Your project inputs,After: Measured energy,57.6,kWh, A,Your project inputs,After: Good bottles,19200,Quantity, A,Step-by-step substitution from the stated inputs,Before (kWh/1000) / 1,0.004,,( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) A,Step-by-step substitution from the stated inputs,Before (kWh/1000) / 2,4.0,kWh/1000,(( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) × 1000) A,Calculated result,Before,4.0,kWh/1000, A,Step-by-step substitution from the stated inputs,After (kWh/1000) / 1,0.003,,( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 19200 Quantity] ) A,Step-by-step substitution from the stated inputs,After (kWh/1000) / 2,3.0,kWh/1000,(( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 19200 Quantity] ) × 1000) A,Calculated result,After,3.0,kWh/1000, A,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 1,0.004,,( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) A,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 2,4.0,,(( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) × 1000) A,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 3,0.003,,( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 19200 Quantity] ) A,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 4,3.0,,(( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 19200 Quantity] ) × 1000) A,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 5,1.0,kWh/1000,((( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) × 1000) − (( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 19200 Quantity] ) × 1000)) A,Calculated result,Reduction,1.0,kWh/1000, A,Step-by-step substitution from the stated inputs,Reduction (%) / 1,0.004,,( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) A,Step-by-step substitution from the stated inputs,Reduction (%) / 2,0.003,,( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 19200 Quantity] ) A,Step-by-step substitution from the stated inputs,Reduction (%) / 3,0.001,,(( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) − ( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 19200 Quantity] )) A,Step-by-step substitution from the stated inputs,Reduction (%) / 4,0.25,,((( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) − ( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 19200 Quantity] )) ÷ ( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] )) A,Step-by-step substitution from the stated inputs,Reduction (%) / 5,25.0,%,(((( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) − ( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 19200 Quantity] )) ÷ ( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] )) × 100) A,Calculated result,Reduction,25.0,%, B,Your project inputs,Before: Measured energy,96,kWh, B,Your project inputs,Before: Good bottles,24000,Quantity, B,Your project inputs,After: Measured energy,57.6,kWh, B,Your project inputs,After: Good bottles,28800,Quantity, B,Step-by-step substitution from the stated inputs,Before (kWh/1000) / 1,0.004,,( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) B,Step-by-step substitution from the stated inputs,Before (kWh/1000) / 2,4.0,kWh/1000,(( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) × 1000) B,Calculated result,Before,4.0,kWh/1000, B,Step-by-step substitution from the stated inputs,After (kWh/1000) / 1,0.002,,( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 28800 Quantity] ) B,Step-by-step substitution from the stated inputs,After (kWh/1000) / 2,2.0,kWh/1000,(( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 28800 Quantity] ) × 1000) B,Calculated result,After,2.0,kWh/1000, B,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 1,0.004,,( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) B,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 2,4.0,,(( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) × 1000) B,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 3,0.002,,( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 28800 Quantity] ) B,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 4,2.0,,(( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 28800 Quantity] ) × 1000) B,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 5,2.0,kWh/1000,((( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) × 1000) − (( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 28800 Quantity] ) × 1000)) B,Calculated result,Reduction,2.0,kWh/1000, B,Step-by-step substitution from the stated inputs,Reduction (%) / 1,0.004,,( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) B,Step-by-step substitution from the stated inputs,Reduction (%) / 2,0.002,,( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 28800 Quantity] ) B,Step-by-step substitution from the stated inputs,Reduction (%) / 3,0.002,,(( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) − ( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 28800 Quantity] )) B,Step-by-step substitution from the stated inputs,Reduction (%) / 4,0.5,,((( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) − ( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 28800 Quantity] )) ÷ ( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] )) B,Step-by-step substitution from the stated inputs,Reduction (%) / 5,50.0,%,(((( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) − ( [After: Measured energy: 57.6 kWh] ÷ [After: Good bottles: 28800 Quantity] )) ÷ ( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] )) × 100) B,Calculated result,Reduction,50.0,%, C,Your project inputs,Before: Measured energy,96,kWh, C,Your project inputs,Before: Good bottles,24000,Quantity, C,Your project inputs,After: Measured energy,86.4,kWh, C,Your project inputs,After: Good bottles,19200,Quantity, C,Step-by-step substitution from the stated inputs,Before (kWh/1000) / 1,0.004,,( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) C,Step-by-step substitution from the stated inputs,Before (kWh/1000) / 2,4.0,kWh/1000,(( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) × 1000) C,Calculated result,Before,4.0,kWh/1000, C,Step-by-step substitution from the stated inputs,After (kWh/1000) / 1,0.0045,,( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 19200 Quantity] ) C,Step-by-step substitution from the stated inputs,After (kWh/1000) / 2,4.5,kWh/1000,(( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 19200 Quantity] ) × 1000) C,Calculated result,After,4.5,kWh/1000, C,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 1,0.004,,( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) C,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 2,4.0,,(( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) × 1000) C,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 3,0.0045,,( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 19200 Quantity] ) C,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 4,4.5,,(( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 19200 Quantity] ) × 1000) C,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 5,-0.5,kWh/1000,((( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) × 1000) − (( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 19200 Quantity] ) × 1000)) C,Calculated result,Reduction,-0.5,kWh/1000, C,Step-by-step substitution from the stated inputs,Reduction (%) / 1,0.004,,( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) C,Step-by-step substitution from the stated inputs,Reduction (%) / 2,0.0045,,( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 19200 Quantity] ) C,Step-by-step substitution from the stated inputs,Reduction (%) / 3,-0.0005,,(( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) − ( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 19200 Quantity] )) C,Step-by-step substitution from the stated inputs,Reduction (%) / 4,-0.125,,((( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) − ( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 19200 Quantity] )) ÷ ( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] )) C,Step-by-step substitution from the stated inputs,Reduction (%) / 5,-12.5,%,(((( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) − ( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 19200 Quantity] )) ÷ ( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] )) × 100) C,Calculated result,Reduction,-12.5,%, D,Your project inputs,Before: Measured energy,96,kWh, D,Your project inputs,Before: Good bottles,24000,Quantity, D,Your project inputs,After: Measured energy,86.4,kWh, D,Your project inputs,After: Good bottles,28800,Quantity, D,Step-by-step substitution from the stated inputs,Before (kWh/1000) / 1,0.004,,( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) D,Step-by-step substitution from the stated inputs,Before (kWh/1000) / 2,4.0,kWh/1000,(( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) × 1000) D,Calculated result,Before,4.0,kWh/1000, D,Step-by-step substitution from the stated inputs,After (kWh/1000) / 1,0.003,,( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 28800 Quantity] ) D,Step-by-step substitution from the stated inputs,After (kWh/1000) / 2,3.0,kWh/1000,(( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 28800 Quantity] ) × 1000) D,Calculated result,After,3.0,kWh/1000, D,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 1,0.004,,( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) D,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 2,4.0,,(( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) × 1000) D,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 3,0.003,,( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 28800 Quantity] ) D,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 4,3.0,,(( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 28800 Quantity] ) × 1000) D,Step-by-step substitution from the stated inputs,Reduction (kWh/1000) / 5,1.0,kWh/1000,((( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) × 1000) − (( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 28800 Quantity] ) × 1000)) D,Calculated result,Reduction,1.0,kWh/1000, D,Step-by-step substitution from the stated inputs,Reduction (%) / 1,0.004,,( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) D,Step-by-step substitution from the stated inputs,Reduction (%) / 2,0.003,,( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 28800 Quantity] ) D,Step-by-step substitution from the stated inputs,Reduction (%) / 3,0.001,,(( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) − ( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 28800 Quantity] )) D,Step-by-step substitution from the stated inputs,Reduction (%) / 4,0.25,,((( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) − ( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 28800 Quantity] )) ÷ ( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] )) D,Step-by-step substitution from the stated inputs,Reduction (%) / 5,25.0,%,(((( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] ) − ( [After: Measured energy: 86.4 kWh] ÷ [After: Good bottles: 28800 Quantity] )) ÷ ( [Before: Measured energy: 96 kWh] ÷ [Before: Good bottles: 24000 Quantity] )) × 100) D,Calculated result,Reduction,25.0,%, A→D,Separate and combined changes from A,Before / First input alone: C − A,0.0,kWh/1000, A→D,Separate and combined changes from A,Before / Second input alone: B − A,0.0,kWh/1000, A→D,Separate and combined changes from A,Before / Both inputs: D − A,0.0,kWh/1000, A→D,Separate and combined changes from A,Before / Sum of the two separate changes,0.0,kWh/1000, A→D,Separate and combined changes from A,Before / Combined change minus that sum,0.0,kWh/1000, A→D,Separate and combined changes from A,After / First input alone: C − A,1.5,kWh/1000, A→D,Separate and combined changes from A,After / Second input alone: B − A,-1.0,kWh/1000, A→D,Separate and combined changes from A,After / Both inputs: D − A,0.0,kWh/1000, A→D,Separate and combined changes from A,After / Sum of the two separate changes,0.5,kWh/1000, A→D,Separate and combined changes from A,After / Combined change minus that sum,-0.5,kWh/1000, A→D,Separate and combined changes from A,Reduction / First input alone: C − A,-1.5,kWh/1000, A→D,Separate and combined changes from A,Reduction / Second input alone: B − A,1.0,kWh/1000, A→D,Separate and combined changes from A,Reduction / Both inputs: D − A,0.0,kWh/1000, A→D,Separate and combined changes from A,Reduction / Sum of the two separate changes,-0.5,kWh/1000, A→D,Separate and combined changes from A,Reduction / Combined change minus that sum,0.5,kWh/1000, A→D,Separate and combined changes from A,Reduction / First input alone: C − A,-37.5,percentage points, A→D,Separate and combined changes from A,Reduction / Second input alone: B − A,25.0,percentage points, A→D,Separate and combined changes from A,Reduction / Both inputs: D − A,0.0,percentage points, A→D,Separate and combined changes from A,Reduction / Sum of the two separate changes,-12.5,percentage points, A→D,Separate and combined changes from A,Reduction / Combined change minus that sum,12.5,percentage points,