Hypothetical combination,Input or result,Your project inputs / Calculated result,Value,Unit,Operation A,Your project inputs,Heat load,38.4,kW, A,Your project inputs,Temperature rise,4.8,K, A,Step-by-step substitution from the stated inputs,Flow (L/min) / 1,2304.0,,( [Heat load: 38.4 kW] × 60) A,Step-by-step substitution from the stated inputs,Flow (L/min) / 2,20.0928,,(4.186 × [Temperature rise: 4.8 K] ) A,Step-by-step substitution from the stated inputs,Flow (L/min) / 3,114.66794075489727,L/min,(( [Heat load: 38.4 kW] × 60) ÷ (4.186 × [Temperature rise: 4.8 K] )) A,Calculated result,Flow,114.66794075489727,L/min, B,Your project inputs,Heat load,38.4,kW, B,Your project inputs,Temperature rise,7.2,K, B,Step-by-step substitution from the stated inputs,Flow (L/min) / 1,2304.0,,( [Heat load: 38.4 kW] × 60) B,Step-by-step substitution from the stated inputs,Flow (L/min) / 2,30.1392,,(4.186 × [Temperature rise: 7.2 K] ) B,Step-by-step substitution from the stated inputs,Flow (L/min) / 3,76.44529383659818,L/min,(( [Heat load: 38.4 kW] × 60) ÷ (4.186 × [Temperature rise: 7.2 K] )) B,Calculated result,Flow,76.44529383659818,L/min, C,Your project inputs,Heat load,57.6,kW, C,Your project inputs,Temperature rise,4.8,K, C,Step-by-step substitution from the stated inputs,Flow (L/min) / 1,3456.0,,( [Heat load: 57.6 kW] × 60) C,Step-by-step substitution from the stated inputs,Flow (L/min) / 2,20.0928,,(4.186 × [Temperature rise: 4.8 K] ) C,Step-by-step substitution from the stated inputs,Flow (L/min) / 3,172.00191113234592,L/min,(( [Heat load: 57.6 kW] × 60) ÷ (4.186 × [Temperature rise: 4.8 K] )) C,Calculated result,Flow,172.00191113234592,L/min, D,Your project inputs,Heat load,57.6,kW, D,Your project inputs,Temperature rise,7.2,K, D,Step-by-step substitution from the stated inputs,Flow (L/min) / 1,3456.0,,( [Heat load: 57.6 kW] × 60) D,Step-by-step substitution from the stated inputs,Flow (L/min) / 2,30.1392,,(4.186 × [Temperature rise: 7.2 K] ) D,Step-by-step substitution from the stated inputs,Flow (L/min) / 3,114.66794075489727,L/min,(( [Heat load: 57.6 kW] × 60) ÷ (4.186 × [Temperature rise: 7.2 K] )) D,Calculated result,Flow,114.66794075489727,L/min, A→D,Separate and combined changes from A,Flow / First input alone: C − A,57.33397037744864,L/min, A→D,Separate and combined changes from A,Flow / Second input alone: B − A,-38.22264691829909,L/min, A→D,Separate and combined changes from A,Flow / Both inputs: D − A,0.0,L/min, A→D,Separate and combined changes from A,Flow / Sum of the two separate changes,19.111323459149546,L/min, A→D,Separate and combined changes from A,Flow / Combined change minus that sum,-19.111323459149546,L/min,